<ErrorNumber>17692</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: Light level too low for Beam Pointing
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
</text></DescriptionText>
<DescriptionText><text>
Normally means that the laser is not really on so check laser setpoint and
media selection.
</text></DescriptionText>
<DescriptionText><text>
Due to a firmware bug in thermal head firmware versions prior to 1.56 this
error message could also occur if light level on one of the sensors is too
high. This can be very confusing if the laser is clearly on yet the error
message says light level to low. This situation can easy happen if the beam
pointing rod current is completely wrong. To recover from this situation enter
"laser current 20", "head bp on" and wait for several minutes. After this the
rod current should be properly set and you should now be able to issue "laser
on" successfully.
</text></DescriptionText>
<DescriptionText><text>
If you have thermal head version 1.56 it is easily possible to diagnose the
exact problem by using the internal data collection capabilities (see release
notes or head diag0 information). Also with 1.56 the command "laser test" may
diagnose the problem.
</text></DescriptionText>
<DescriptionText><text>
Note that due to a programming error, this error has been defined for both
the green and thermal heads.
</text></DescriptionText>
<DescriptionText><text>
Thermal: Light level too low for Beam Pointing
</text></DescriptionText>
<DescriptionText><text>
The error indicates that beam-pointing is on but the laser is off ( or having
serious problems ).  There is insufficient signal level for the beam-pointing
( for twenty iterations the sum of the beam-pointing sensors was less than
fifty ).
</text></DescriptionText>
<DescriptionText><text>
The Thermal Head Troubleshooting document includes a beam-pointing test.  The
test turns on the laser and the beam-pointing and verifies operation of the
beam-pointing by moving the laser from one side to the other while monitoring
the beam-pointing sensor readings.
</text></DescriptionText>
<DescriptionText><text>
Green: actuators initialized ok
</text></DescriptionText>
<DescriptionText><text>
The exposure head has successfully finished initialization.  This is not an
error message.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Thermal: The Thermal Head Troubleshooting document includes a beam-pointing
test.
</text></DescriptionText>
<DescriptionText><text>
Green: This message does not indicate an error.  It can be safely ignore.
</text></DescriptionText>
</OperatorAction>
<Cause>
Thermal: There is insufficient signal level for the beam-pointing ( for twenty
iterations the sum of the beam-pointing sensors was less than fifty ).
</Cause>
<Cause>
Green: Head actuators all initialized successfully.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/laser_on.xml</LinkAddress><LinkTitle>Command: laser on</LinkTitle></Link>
<Link><LinkAddress>../commands/laser_current.xml</LinkAddress><LinkTitle>Command: laser current</LinkTitle></Link>
<Link><LinkAddress>../commands/laser_test.xml</LinkAddress><LinkTitle>Command: laser test</LinkTitle></Link>
<Link><LinkAddress>../commands/head_bp.xml</LinkAddress><LinkTitle>Command: head bp</LinkTitle></Link>
<Link><LinkAddress>../nvs/head_cfg_lsrmode.xml</LinkAddress><LinkTitle>NVS: head lsrmode</LinkTitle></Link>
<Link><LinkAddress>../nvs/head_cfg_diag0.xml</LinkAddress><LinkTitle>NVS: head diag0</LinkTitle></Link>
<Link><LinkAddress>../nvs/hdm_cal_wpower.xml</LinkAddress><LinkTitle>NVS: hdm wpower</LinkTitle></Link>
<Link><LinkAddress>../nvs/hdp_cfg_fnm.xml</LinkAddress><LinkTitle>NVS: hdp fnm</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:41 2008 PST